PRODUCTS INFO
 Aluminum wire
 Paper-covered aluminum wire
 Nomax paper covered aluminum wire
 Film covered aluminum wire
 Glass-fibre covered aluminum wire

Product

←Your current location   

Glass-fibre covered aluminum wire



Glass-fibre covered aluminum wire

◆Technical parameter of Fiberglass covered film coiling wire

No. Standard item Technical parameter Standard number Category Fiberglass covered round wire Double-fiberglass covered flat wire Fiberglass covered enameled flat wire Fiberglass covered film-coiling flat wire Testing method
GB7676.2-87 GB7672.3-87 GB7672.4-87 GB7672.5-87 GB7672.6-87
1 Insulation thicknessmm
Round wire(D-d)
Flat wire(A-a)
Nominal diametermm
0.30≤d≤3.00
3.00<d≤34.00
4.00<d≤5.00
Insulation thickness
Thin Thick
0.12 0.25
0.20 0.30
0.25 0.35
Extension rate
%
-20
Nominal diametermm
0.53≤d≤0.75
0.80≤d≤1.00
1.06≤d≤1.50
1.60≤d≤2.50
Deviation
%
-20
Insulation thicknessMM
0.2
0.3
0.4
0.5
Deviation
%
-20
Insulation thicknessMM
0.3
0.4
0.5
Deviation
%
-20
Insulation thicknessMM
0.4
0.5
0.6
Deviation
%
-15
7672.1-87GB7672.1-87
2 Extension rate Round copper wire size
Nominal diametermm
0.30≤d≤4.00
0.40<d≤1.50
1.50<d≤5.00
Extension rate%
20
25
30
Round aluminum wire
Nominal diametermm
0.30≤d≤1.00
1.00≤d≤5.00
  Nominal diametermm
a≤0.25
a>2.50
Extension rate%
aluminum
17
17
  GB/T4074.3-99
3 Coiling and bending 标称直径mm
d≤4.00
0.40<d≤0.60
0.60<d≤0.80
0.80<d≤1.00
1.00<d≤1.50
1.50<d≤2.00
2.00<d≤3.0
3.0<d≤4.0
4.0<d≤5.0
Nominal diametermm
2
3
4
5
8
10
15
20
25
No coiling requirement
This table is suitable for sample coiling of penetration voltage
0.53<d≤0.60
0.60<d≤0.80
0.80<d≤1.00
1.00<d≤1.50
1.50<d≤2.00
2.00<d≤2.50
  Nominal diametermm
200≤b≤8.00
8.00<b≤16.00
0.80<b≤5.60
Round bar diametermm
10b
15b
10a
 

GB/T4074.3-99

GB/T4074.3-99

4 Adhesion Nominal diametermm
d≤2.50
d≥2.50
Extension rate%
Aluminum
10
10
stretch 15%   Conductor

aluminum
Nominal diametermm

Overall size
stretch%
10
Conductor stretch%

10
GB/T4074.3-99
5 Penetration voltage Nominal diametermm
Insulation thicknessmm
0.12
0.25
0.20
0.30
0.25
0.35
Penetration voltageV
250
450
350
500
450
550
Insulation thickness
Thin
Thick
Penetration voltageV
800
1000
Insulation thicknessmm
0.2
0.3
0.4
0.5
Penetration voltageV
300
400
500
350
Insulation thicknessmm
0.3
0.4
0.5

Penetration voltageV
SBQB
1200
1400

SBEQB
1600
1800
2000

Insulation thicknessmm
0.4
0.5
0.6
Penetration voltageV
2500
4500
5500
GB/t4074.5-99
6 DC resistance It should be in accordance with technical requirements for DC resistance value R20 per unit length when the round aluminum conductor is at 20. 

R20= P20/Smin
Above Smin means the minimum section area of conductor, which is calculated by minimum size of a/b and maximum size of r
Smin=amin×bmin-0.8584r2max
For aluminum conductor:P20=1/35.7Ωmm2/m

GB/Y4074.5-99
















 

WEBSITE WXFL Wuxi Feilong Electromagnetic Wire Co., Ltd Tel:0510-85306575 85312666 Fax:0510-85302660
Http://www.wxfl.net E-mail:wxfl-cn@163.com